Electronic components stored in uncontrolled conditions degrade. For a consumer product with a two-year life that is an inconvenience. For a defence platform or aerospace system expected to stay operational for 20 to 30 years, it can end a programme.
This guide sets out the storage conditions, packaging standards and controlled-atmosphere techniques required for long-term electronic component storage, with specific reference to the demands of defence and aerospace procurement. The figures below reflect Force Technologies' own practice at its nitrogen-atmosphere storage facility, not generic industry assumption.
Key takeaways
- Store electronic components at 15°C to 25°C and below 40% RH, in a nitrogen atmosphere holding oxygen below 0.1% for any storage beyond five years.
- Yes, components go bad in storage. Oxidation of leads, moisture ingress and electrostatic discharge are the main mechanisms, and all three are preventable.
- Under controlled conditions, semiconductors stay specification compliant for at least 15 to 20 years.
- Defence and aerospace storage requires continuous environmental monitoring and traceability records to AS9100 Rev D.
Do Electronics Go Bad in Storage
Yes, electronic components go bad in storage when conditions are not controlled, through oxidation of metal leads, moisture ingress into plastic packages, electrostatic discharge damage and stress from temperature cycling. None of these is a theoretical risk. Each is documented, measurable and preventable with the right storage approach.
Oxidation of leads. When solder finishes, gold bond wires and copper leadframes are exposed to atmospheric oxygen they oxidise. On component leads this reduces solderability, so parts cannot be reliably assembled onto a board without defects. Tin whisker growth is an additional long-term risk on lead-free finishes, particularly in warm, humid conditions. Removing the oxygen removes the mechanism, which is why a nitrogen atmosphere below 0.1% oxygen is the single most effective intervention.
Moisture ingress. Plastic-encapsulated ICs absorb atmospheric moisture. During reflow soldering that trapped moisture vaporises, and the pressure can cause internal delamination or cracking, a failure known as the popcorn effect. The JEDEC J-STD-033 standard classifies parts by Moisture Sensitivity Level (MSL) and sets a floor life for each, after which a component must be baked out before assembly.
Electrostatic discharge. ESD damage to CMOS gate oxides and other sensitive junctions is often latent. The component passes initial electrical test but fails prematurely in service. Even low-voltage events, imperceptible to touch, can permanently alter device characteristics, which is why ESD-safe packaging and handling by trained personnel are non-negotiable.
Temperature cycling. Extreme or inconsistent temperatures place physical stress on components, and can cause warping or delamination over time. Stable temperature matters as much as the absolute figure.
What Temperature Should a Component Storage Room Maintain
A component storage room should maintain a stable temperature between 15°C and 25°C, with relative humidity held below 40% RH. Stability matters alongside the figure itself, since temperature cycling introduces mechanical stress even when the average stays in range. This reflects Force Technologies' own practice, and the approach is supported by the ZVEI guideline for the long-term storage of electronic components, modules and devices, which sets out controlled-storage practice for components held over extended periods.
For storage beyond five years, or for high-value obsolete parts, a nitrogen-purged atmosphere is added on top of temperature and humidity control. Nitrogen displaces oxygen to below 0.1%, effectively halting the oxidation that temperature and humidity control alone cannot prevent. Setting this up properly, with generated nitrogen, continuous monitoring and audit-ready records, is exactly what our Titan Long Term Storage service provides.
Storage Best Practices
The table below summarises the controlled conditions required for long-term electronic component storage.
| Factor | Requirement | Why it matters |
|---|---|---|
| Temperature | 15°C to 25°C, stable, minimal cycling | Prevents thermal stress, warping and delamination |
| Relative humidity, packaged parts | 30% to 40% RH | Limits moisture absorption and corrosion |
| Relative humidity, plastic parts in dry storage | Below 5% RH in nitrogen dry cabinets | Suspends MSL floor life and gives effectively indefinite shelf life per J-STD-033 |
| Relative humidity, bare die | Around 7% to 30% RH | Avoids static build-up and damage caused by over-drying raw die |
| Atmosphere | Nitrogen purged, oxygen below 0.1% | Stops oxidation of leads, bond wires and solder finishes |
| ESD control | ESD-safe packaging and handling by trained personnel | Prevents latent electrostatic damage to sensitive junctions |
| Packaging | Moisture barrier bag with desiccant and humidity indicator card, to J-STD-033 | Controls residual moisture and evidences storage condition |
| Monitoring | Continuous temperature and humidity logging | Provides audit-ready traceability |
| Certification | AS9100 Rev D and BS9000 records | Meets defence and aerospace procurement requirements |
The Role of Nitrogen in Long-Term Storage
Nitrogen purging eliminates oxygen from the storage environment, preventing oxidation of leads, die-attach materials, gold bond wires and solder finishes. Standard air is roughly 21% oxygen, enough to oxidise tin and copper surfaces measurably over months even at low humidity. Reducing oxygen below 0.1% brings the oxidation rate down to negligible levels.
Nitrogen storage is most valuable for bare die awaiting assembly, obsolete parts where the stored stock is the entire remaining supply, moisture-sensitive devices where a dry nitrogen atmosphere extends floor life, and long-lifecycle programmes where parts must remain viable for 15 to 20 years. Force Technologies uses generated nitrogen to maintain an inert atmosphere within temperature and humidity-controlled, ESD-safe cabinets, following J-STD-033 D and JEP 160 guidance. This capability was expanded in 2025 with additional nitrogen dry storage cabinets.
Standards and Traceability for Defence and Aerospace Programmes
Defence and aerospace programmes require documented traceability of storage conditions, including continuous temperature and humidity logging, lot traceability back to the original manufacturer certificate, and audit-ready records to AS9100 Rev D and BS9000. This is what separates managed long-term storage from placing parts in a cool, dry room, and it matters during procurement audits, airworthiness reviews and Diminishing Manufacturing Sources and Material Shortages (DMSMS) assessments.
Force Technologies holds AS9100 Rev D and BS9000 certification and is registered with JOSCAR, the Joint Supply Chain Accreditation Register for defence and aerospace. Stored stock is sampled periodically for visual and electrical compliance, and where a programme demands it, Destructive Physical Analysis (DPA) confirms internal condition against the original datasheet.
How Long Can Electronic Components Be Stored
Semiconductors stored in controlled conditions, below 25°C and below 40% RH, remain functional and specification compliant for at least 15 to 20 years. There is no single universal shelf life, because it depends on package type, Moisture Sensitivity Level, lead finish and storage atmosphere. Ceramic and hermetic packages are far less moisture-sensitive than plastic-encapsulated devices, and a nitrogen atmosphere extends effective storage life across all types by removing oxidation.
Force Technologies has run its long-term storage and assembly programme for over 20 years, storing not only packaged components but also bare die, lids, epoxies and packaging materials, so the complete build capability is preserved rather than the component alone.
Talk to Force Technologies About Long-Term Storage
Force Technologies provides long-term storage and assembly for defence, aerospace, medical and industrial programmes. Our nitrogen-atmosphere storage facility offers temperature and humidity-controlled, ESD-safe storage with continuous monitoring and traceability records certified to AS9100 Rev D and BS9000. Whether you are facing an end-of-life notice, planning for a long-lifecycle platform or securing a stock of obsolete parts, the team can help you build a storage strategy that holds up over the years the programme needs.
Frequently asked questions
Do electronics go bad in storage?
Yes. Electronic components degrade in storage when conditions are not controlled, mainly through oxidation of leads, moisture ingress into plastic packages, and electrostatic discharge. In controlled conditions of 15°C to 25°C, below 40% RH and a nitrogen atmosphere, components remain specification compliant for 15 to 20 years. In poor conditions, degradation can begin within months.
What temperature should a component storage room maintain?
A component storage room should maintain a stable temperature of 15°C to 25°C with relative humidity below 40% RH. For long-term storage beyond five years, a nitrogen-purged atmosphere holding oxygen below 0.1% is added to prevent oxidation. This is consistent with Force Technologies' own practice and with the ZVEI guideline for long-term storage of electronic components.
How long can electronic components be stored?
Under controlled conditions, temperature below 25°C, humidity below 40% RH and a nitrogen atmosphere, electronic components can be stored for at least 15 to 20 years without meaningful degradation. Actual life depends on package type, Moisture Sensitivity Level and lead finish. Periodic sampling and, where required, requalification testing confirm parts remain within specification.
Why is nitrogen used for long-term component storage?
Nitrogen is an inert gas that displaces oxygen from the storage environment. Atmospheric oxygen oxidises solder finishes, copper leadframes and gold bond wires, reducing solderability. A nitrogen atmosphere below 0.1% oxygen reduces the oxidation rate to negligible levels, extending effective storage life. Force Technologies' Titan Long Term Storage facility uses nitrogen-purged cabinets with continuous monitoring to maintain these conditions.

Written by
Ben SavageApplications Manager, Force Technologies
Ben Savage joined Force back in 2006, starting out as a technician and now holds the title of Applications Manager. Boasting 20 years living and breathing obsolete semiconductors, his day-to-day role is heading up the daily engineering requirements that get sent in from our global customer base.
When not working, Ben can be found spending time with his wife, two children and various hobbies.
Certifications:
Ben holds Member level with The Institute of Obsolescence Management and has written and presented numerous presentations/blogs over the years detailing Force products/services and new technologies.
Social Media:
You can keep up to date with Ben’s thoughts and get in touch with him via LinkedIn: